Large-scale single-cell arrays are urgently required for current high-throughput screening of cell function and heterogeneity. However, the rapid and convenient generation of large-scale single-cell array in a multiplex and universal manner is not yet well established. In this paper, we report a simple and reliable method for the generation of a single-cell array by combining pneumatic microvalve arrays (PμVAs) and hydrodynamic single-cell trapping sites in a single microfluidic device. The PμVAs, which can be precisely controlled by actuated pressures, were designed to guide multiple types of cells being trapped in the corresponding single-cell trapping sites located in the fluidic channel. According to the theoretical demonstration and computational simulation, we successfully realized a multiplex single-cell array with three different types of cells by a step-by-step protocol. Furthermore, the analysis of cellular esterase heterogeneity of the three types of cells was concurrently implemented in the device as a proof-of-concept experiment. All the results demonstrated that the method developed in the current study could be applied for the generation of large-scale single-cell array with multiple cell types, which would be also promising and helpful for single-cell-based high-throughput drug test, multipurpose immunosensor and clinical diagnosis.
Keywords
Related Topics
Physical Sciences and Engineering
Chemistry
Analytical Chemistry
Authors
Lei Zhao, Chao Ma, Shaofei Shen, Chang Tian, Juan Xu, Qin Tu, Tianbao Li, Yaolei Wang, Jinyi Wang,