Article ID Journal Published Year Pages File Type
727178 Journal of Electrostatics 2009 10 Pages PDF
Abstract

Potential measurement can be applied to electrical capacitance tomography (ECT) systems. However, the relationship between potential and the capacitance is not well understood. This paper reveals that a potential is dependent on the capacitance ratio for a given excitation voltage, independent of capacitance themselves. The conditions for using this method are discussed. Finally, image reconstruction based on the Generic Algorithm for Electrical Capacitance Tomography (GA-ECT) is implemented satisfactorily for square and circular sensors respectively.

Related Topics
Physical Sciences and Engineering Engineering Electrical and Electronic Engineering