Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
727721 | Measurement | 2010 | 8 Pages |
Abstract
This paper introduces a new close-range photogrammetric bridge deflection measurement system that has high accuracy and efficiency, and can be conveniently used by engineers without help from professional surveyors. After a general description of a photogrammetric bridge deflection measurement system, four critical components of the system are addressed in detail: camera selection and settings; camera calibration; network control (reference system and scale); and camera placement. The system configuration is introduced and the system is verified through the laboratory and field tests.
Related Topics
Physical Sciences and Engineering
Engineering
Control and Systems Engineering
Authors
Ruinian Jiang, David V. Jauregui,