Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
727747 | Measurement | 2010 | 8 Pages |
Abstract
In this work a difference temperature-to-time converter is shown using two thermistors working in a DC generalized impedance converter. Voltage drop in one of the thermistors depends on the temperature difference between them. This voltage is compared with a time varying exponential reference voltage obtaining a time interval at the output circuit with good linear dependence with respect to the input temperature difference. Experimental results are obtained showing a new generalized impedance converter application. The implemented circuit was characterized by a repeatability of 1.0%, a reproducibility of 4.5% and a relative accuracy of 1.3%.
Keywords
Related Topics
Physical Sciences and Engineering
Engineering
Control and Systems Engineering
Authors
D. Ramírez Muñoz, E. Castro Montero, J. Sánchez Moreno, S. Casans Berga, A.E. Navarro Antón, J. Fong Barrio, A. Salazar Mustelier,