Article ID Journal Published Year Pages File Type
729796 Measurement 2015 7 Pages PDF
Abstract

•The article presents the novel NIR-FBG based sensor system for dynamic measurement.•Impact location determination test was done using the proposed FBG system.•The results show the errors were below 10%.

An integration of Structural Health Monitoring (SHM) into composite structures contribute towards the development of smart composites structure. Smart-structure offers an ability have a continuous and real-time information of its circumstances under critical loading applications. One of the main objectives in this research study was the development of the Fiber Bragg grating (FBG) sensor system for SHM of thin composite laminates. Not only that, this work has been utilizing the FBG sensors in the Near Infra-red (NIR) range; ∼830 nm, as an alternative to the applications of the conventional 1550 nm FBG sensors. The capability of this sensor system was validated with the impact location determination test on a thin composite plate. It showed a very promising result whereby the relative error falls below 10%.

Related Topics
Physical Sciences and Engineering Engineering Control and Systems Engineering
Authors
, , ,