Article ID Journal Published Year Pages File Type
735807 Optics and Lasers in Engineering 2011 7 Pages PDF
Abstract

For checking the collimation of an optical beam Fourier fringe analysis has been incorporated into the wedge plate interferometric setup. Typical interferograms corresponding to ‘in-focus’, ‘at-focus’ and ‘out-of-focus’ positions of an optical beam have been recorded. As per the testing procedure, FFT of the recorded interferometer is computed digitally, and necessary processing for direct determination of phase is undertaken. Finally, the phase data is unwrapped and plotted as a function of pixel position along the direction perpendicular to the shear. The slope of the phase provides the information regarding collimation position of the collimator. As the collimation position is detected by the direct measurement of the phase over the whole area of the interferogram, high accuracy, reliability and precision are achieved.

► Direct phase measurement using the Fourier fringe analysis has been used for collimation testing. ► Very simple, inexpensive and robust design of experimental setup. ► High accuracy, reliability and precision have been achieved.

Related Topics
Physical Sciences and Engineering Engineering Electrical and Electronic Engineering
Authors
, ,