Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
740613 | Sensors and Actuators A: Physical | 2006 | 6 Pages |
Abstract
The design of a mixed-signal integrated circuit interface for the control of the heating resistance and reading of the chemically sensitive resistance of metal oxide chemical sensor arrays is reported. It contains in a single integrated circuit all the analog front-end to operate four MOX sensors while the control logic will be implemented on a microcontroller. Each heater is controlled from a dedicated digital to analog converter. Provision has been taken for both polysilicon and Pt heater control. The design has been realized in a standard 0.7 μm CMOS process.
Keywords
Related Topics
Physical Sciences and Engineering
Chemistry
Electrochemistry
Authors
P. Robogiannakis, S. Chatzandroulis, C. Tsamis,