Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
753263 | Applied Acoustics | 2016 | 6 Pages |
Abstract
The subject of this paper is the long distance propagation of train noise. The sound exposure level of train noise LAE was measured. To describe the results of measurements, a semi-analytical model was used. It takes into account the wave-front divergence, air absorption, ground effect, and the turbulence destroying the coherent nature of the ground effect. The model contains three adjustable parameters that must be estimated at the site. To verify the model, we performed measurements of LAE at the distance D = 450 m from the train track center. The difference between the calculated and measured mean values of LAE equals 1.3 dB.
Keywords
Related Topics
Physical Sciences and Engineering
Engineering
Mechanical Engineering
Authors
Roman Gołębiewski,