Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
7539788 | Journal of Energy Storage | 2018 | 11 Pages |
Abstract
Thermal energy storage (TES) in a packed bed exemplifies important technology for concentrated solar thermal (CST) applications such as electricity production, desalination, enhanced oil recovery, fuel production and chemical processing. In this study, the cyclic charge-discharge behavior of packed bed TES was studied experimentally using alumina beads as packing material. Air was used as heat transfer fluid (HTF) with an inlet temperature of 150â¯Â°C. This paper shows the effect of flow rates, partial charge-discharge cycling, and storage hold time on the exergetic efficiencies. The results indicate that the exergy efficiency increases from 35.7% to 55.4% with increasing flow rate from 0.0020 to 0.0061â¯m3/s. The exergy decays for multiple cycles before reaching a steady state. Over partial charge-discharge cycles at flow rates of 0.0020, 0.0034, 0.0048, and 0.0061â¯m3/s, the exergetic efficiency decays from 59.8% to 50.2%, 72.5% to 61.2%, 79.0% to 66.2%, and 83.1% to 69.2%, respectively. Heat losses and axial thermal dispersion are two important variables that affect the exergy efficiency, and the individual contributions were estimated via a model for the partial cycles. Heat losses were considered for three durations of holding: no hold, 30â¯min hold and 120â¯min hold. The exergy efficiency decays from 53.2% to 31.0% from no hold to 120â¯min hold due to the heat lost to the ambient.
Keywords
Related Topics
Physical Sciences and Engineering
Energy
Energy (General)
Authors
Mohammad M.S. Al-Azawii, Carter Theade, Megan Danczyk, Erick Johnson, Ryan Anderson,