Article ID Journal Published Year Pages File Type
754535 Applied Acoustics 2011 6 Pages PDF
Abstract

In this study, a simple isolation method of ground vibration is proposed by using a dynamic damper and a trench, which is feasible for temporary use during a construction period. The ground is modeled as a two-dimensional plane model. Periodic impulsive excitation acts at one point on the ground surface, and the vibrations are measured at several evaluation points on the ground surface. A simple dynamic damper composed of a weight and a restoring element is set up at the ground surface or in the shallow trench, and the vibration isolation effect is examined. The simulation shows that the ground vibration can be isolated when the dynamic damper is set near the excitation point on the ground surface, and setting the dynamic damper in a shallow trench has almost the same isolation effect as that in a deep trench. The results indicate that the proposed isolation method is feasible for actual application.

Related Topics
Physical Sciences and Engineering Engineering Mechanical Engineering
Authors
, , , ,