Al–Si closed-cell aluminum foam sandwich panels (1240 mm × 1100 mm) of different thicknesses and different densities were prepared by molten body transitional foaming process in Northeastern University. The experiments were carried out to investigate the sound insulation property of Al–Si closed-cell aluminum foam sandwich panels of different thicknesses and different densities under different frequencies (100–4000 Hz). Results show that sound reduction index (R) is small under low frequencies, large under high frequencies; thickness affects the sound insulation property of material obviously: when the thicknesses of Al–Si closed-cell aluminum foam sandwich panels are 12, 22, and 32 mm, the corresponding weighted sound reduction indices (RW) are 26.3, 32.2, and 34.6 dB, respectively, the rising trend tempered; the increase of density of Al–Si closed-cell aluminum foam can also increase the sound insulation property: when the densities of aluminum foam are 0.31, 0.51, and 0.67 g/cm3, the corresponding weighted sound reduction indices (RW) are 28.9, 34.3, and 34.6 dB, the increasing value mitigating.