Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
7557037 | Analytical Biochemistry | 2018 | 7 Pages |
Abstract
We previously identified four glycan tumor marker candidates using a HPLC-based method. One candidate was sialyl Tn (STN), NeuAcα2-6-GalNAc. In this study, glycans were prepared from sera by hydrazine treatment followed by fluorescent labeling with aminopyridine. Pyridylaminated-STN levels of 147 gastric cancer, 85 pancreatic cancer and 10 cholangiocarcinoma patients together with 102 normal controls were accurately quantified using HPLC separation followed by selected reaction monitoring (SRM) assay, which used a stable isotope, tetradeuterium-labeled pyridylamino glycan as an internal standard. Additionally, STN values were also quantified using conventional competitive inhibition radioimmunoassay (RIA). The two STN levels determined by RIA and SRM gave a similar distribution pattern in sera. STN levels were increased in sera from cancer patients compared to those from normal controls. Moreover, the STN levels in sera of cancer patients determined by the two different assay procedures showed a good correlation (i.e., correlation coefficient >0.9). Our results suggest it may be better to determine STN levels using SRM instead of RIA.
Keywords
Related Topics
Physical Sciences and Engineering
Chemistry
Analytical Chemistry
Authors
Miki Tanaka-Okamoto, Ken Hanzawa, Mikio Mukai, Hidenori Takahashi, Masayuki Ohue, Yasuhide Miyamoto,