Article ID Journal Published Year Pages File Type
7601122 Food Chemistry 2014 6 Pages PDF
Abstract
A capillary electrophoresis method to determine four sulfonylureas in grain samples was developed using 10 mM of 1-butyl-3-methyl imidazolium tetrafluoroborate (bminBF4) as electrophoretic buffer solution. 2 mg L−1 of Surfactant Coated-Single Wall-Carbon Nanotubes (SC-SWCNTs) was added to the buffer solution to improve the resolution. In this way, the separation of nicosulfuron, ethoxysulfuron, sulfometuron methyl and chlorsulfuron was carried out in 16 min without using organic solvents. A clean up-preconcentration procedure was done prior to inject the sample into the CE instrument, in order to achieve the established maximum residue limits (MRLs). So, the detection limits (LODs) for each analytes were between 16.8 and 26.6 μg kg−1. The relative standard deviations (RSDs) were in the range 1.9-6.7%. A recovery study using the so-called matrix matched calibration demonstrates that no matrix interferences were found throughout the determination. The recovery percentages were ranged between 80% and 113%.
Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry
Authors
, , ,