Abstract

•Combined sensible, latent and thermochemical thermal energy storage systems.•Thermoeconomic analysis of TES system.•Dead state temperature effects on thermoeconomics.

This study deals with exergetic and thermoeconomic analyses of thermal energy storage (TES) systems, such as latent, sensible and thermochemical options coupled with different units for building heating applications under varying reference (dead-state) temperatures of 8 °C, 9 °C and 10 °C, respectively. It is found that the variation reference temperature affects the thermoeconomic parameters. The exergetic cost of the system becomes higher at the higher reference conditions, as directly proportional to the varying dead state conditions. It also becomes minimum at 8 °C reference temperature as 196.96 $/h while it is maximum at 10 °C dead-state temperature with 357.60 $/h. Furthermore, the maximum capital cost of the equipment is determined for the thermochemical TES as 4.612 $/h. So, the better optimization of this equipment may be considered.

Related Topics
Physical Sciences and Engineering Energy Energy (General)