Abstract
After optimizing the extraction conditions, the intraday relative standard deviation values for a double distilled water spiked with the selected triazines were in range of 8.9-9.5% (n = 3) while the limits of detection were between 0.03-0.09 ng mLâ1. The linearity of the method was in the concentration range of 0.1-500 ng mLâ1. The proficiency of the developed method was validated by analyzing paddy, well and tap water samples and the relative recovery values were found to be in the range of 83-95% under the optimized conditions.