Abstract
A rapid resolution liquid chromatography (RRLC) method was developed and validated for the simultaneous determination of nine carotenoids compounds (violaxanthin, lutein, zeaxanthin, β-cryptoxanthin, α-carotene, β-carotene, lycopene, phytoene, phytofluene), four tocopherols and four chlorophylls and derivates (chlorophylls and pheophytins). The methodology consisted in a micro-extraction procedure with or without saponification and subsequent analysis by RRLC. The limits of detection were <0.07 μg for carotenoids and tocopherols and <0.08 μg for chlorophylls and derivatives. The overall precision values (intra- and inter-day) were lower than 12% when samples were not saponified and <27.6%, when the saponification step was performed. The recovery of the method without the saponification step ranged from 92% to 107%, whilst that when saponification was carried out ranged from 60% for α-tocopherol to 82% for β-carotene. Finally, the applicability of the method was demonstrated by the identification and quantification of isoprenoids in different samples. The methodology is appropriate for the high-throughput screening of dietary isoprenoids in fruits and vegetables.