Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
7615669 | Journal of Chromatography B | 2018 | 7 Pages |
Abstract
A sensitive and specific method, utilising high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) was developed for the quantitative determination of amlodipine in dried blood spot (DBS) samples. Chromatographic separation was achieved using a Waters XBridge C18 column with gradient elution of a mixture of water and acetonitrile containing 0.1% formic acid (v/v). Amlodipine was quantified using a Waters Quattro Premier mass spectrometer coupled with an electro-spray ionization (ESI) source in positive ion mode. The MRM transitions of 408.9âm/z â 238.1 m/z and 408.9 â 294.0âm/z were used to quantify and qualify amlodipine, respectively. The method was validated across the concentration range of 0.5-30 ng/mL by assessing specificity, sensitivity, linearity, precision, accuracy, recovery and matrix effect according to the Food and Drug Administration (FDA) guidelines. This method was also validated clinically within a large pharmacoepidemiological study in which amlodipine blood concentration was determined in patients who had been prescribed this medication.
Related Topics
Physical Sciences and Engineering
Chemistry
Analytical Chemistry
Authors
Gaoyun Chen, Feras Sr, Abdel Al Bawab, James C. McElnay,