Article ID Journal Published Year Pages File Type
762090 Computers & Fluids 2012 7 Pages PDF
Abstract

Pump manufactures normally do not provide performance curves of their pumps working as turbines, especially performance curves of trimmed impellers. Impeller trimming is necessary to adapt to a certain operating condition. Therefore, establishing the correlation of PAT’s performance curve and impeller trims is essential. In this paper, a laboratory model of a pump as turbine (PAT) open test rig was set up. Experimental research was carried out on a single stage centrifugal PAT, performance curves of original impeller, impeller after once and twice trims were acquired. Numerical simulation and analysis were performed on the PAT. The accuracy of CFD was validated through comparison between numerical and experimental data. As impeller diameter is cut down, its geometrical parameters of impeller diameter, blade wrap angle, impeller inlet width and blade inlet angle are changed. So, research on effects of the above four parameters to the performance influence of PAT were carried out using CFD. Through analysis of the predicted performance curves, the reasons for the variation of performance curves after impeller trimming were explored.

► Pump and pump as turbine’s performance curves with original impeller and impeller after twice trims were presented. ► The accuracy of PAT’s performance prediction using CFD was validated. ► Geometric parameters to be changed when trimming impeller influencing PAT’s performance are numerically investigated. ► Reasons for the performance change of PAT as impeller diameter is cut down are explored.

Related Topics
Physical Sciences and Engineering Engineering Computational Mechanics
Authors
, , , ,