Article ID Journal Published Year Pages File Type
764311 Energy Conversion and Management 2012 9 Pages PDF
Abstract

In this paper, the stationary super-capacitors are used to store a metro network regenerative braking energy. In order to estimate the required energy storage systems (ESSs), line 3 of Tehran metro network is modeled through a novel approach, in peak and off-peak conditions based on the real data obtained from Tehran metro office. A useful method is proposed to predict the maximum instantaneous regenerative energy which is delivered to each station before applying ESS and based on that the ESS configuration for each station is determined. Finally, the effectiveness of the proposed ESS is confirmed by economic evaluations and benefit/cost analyses on line 3 of Tehran metro network.

► Super-capacitors are used to store regenerative braking energy in a metro network. ► A novel approach is proposed to model easily and accurately the metro network. ► An efficient approach is proposed to calculate the required super-capacitors. ► Maximum energy saving is around 44% at off-peak period and 42% at peak period. ► Benefit/cost analyses are performed for the suggested ESS.