Article ID Journal Published Year Pages File Type
764927 Energy Conversion and Management 2009 12 Pages PDF
Abstract

Experimental investigation of heat transfer and friction factor characteristics of thermosyphon solar water heater with full length Left–Right twist, twist fitted with rod and spacer at the trailing edge for lengths of 100, 200 and 300 mm for twist ratio 3 and 5 has been studied. The experimental data for plain tube collector has been compared with fundamental equation within a discrepancy of ±7.41% and ±14.97% for Nusselt number and friction factor, respectively. Result shows that the Nusselt number decreases by 11% and 19% for twist fitted with rod and twist with spacer, respectively, when compared with full length twist. Friction factor also decreases by 18% and 29% for twist fitted with rod and spacer, respectively, as compared with full length twist. The heat enhancement in twist fitted with rod at the trailing edge is maximum when compared with twist fitted with spacer because the swirl flow is maintained throughout the length of rod.

Related Topics
Physical Sciences and Engineering Energy Energy (General)
Authors
, , , ,