Article ID Journal Published Year Pages File Type
765248 Energy Conversion and Management 2008 6 Pages PDF
Abstract

Induction motor stalling is one of the important reasons for voltage collapse. This paper presents that, for induction motor stalling diagnosis, it is not necessary to use a third or first order dynamic model of induction motors. Instead, a method is presented based on algebraic calculations for which the steady state model of the induction motor considering different kinds of mechanical loads (constant and variable torque) is added to the power flow equations. Simulation results for a simple system confirm the correctness of the proposed method as compared to dynamic simulation results.

Related Topics
Physical Sciences and Engineering Energy Energy (General)