Article ID Journal Published Year Pages File Type
765282 Case Studies in Thermal Engineering 2016 13 Pages PDF
Abstract

Energy and exergy balances were evaluated for the units that constitute the Aromatics plant of a refinery in Portugal (FAR): pre-distillation (Un-0100), Arosolvan (Un-0200), Parex (Un-0300), Isomar (Un-0400) and production of solvents (Un-0500).The FAR had an overall energy yield of 0.81% and an exergetic efficiency of 65.9%. The equipment with higher energy losses, were the condensers, representing 25.9% of the energy losses, followed by air coolers, with 15.4% of the energy losses. The furnaces were in third place with 14.7% of the energy losses. Most of the energy lost in FAR was due to the cooling process. The irreversibilities observed in the condensers and air coolers were equivalent to 1.61% and 0.86% of the total plant irreversibility. Furnaces represent 14.7% of energy losses, but stand out above the irreversibilities analysis with 14.5% of the total. This equipment presents a high potential of energetic and exergetic performance improving, with natural positive impact on energetic and exergetic performance in the FAR.The unaccounted thermal losses represented 32.9% which is mainly justified by the unknown mass flow rate of the gaseous effluent burned in the flare.

Related Topics
Physical Sciences and Engineering Engineering Mechanical Engineering
Authors
, , ,