Abstract

► We examine microstructure and fracture of stainless steel AISI 310S. ► Pipes were tested after long life application (between 2 and 3 years) at temperatures 600–650 °C. ► Microstructure consisted from σ-phase, sporadically carbides and austenite matrix. ► Fracture surface was transgranular brittle fracture with clevage morphology.