Article ID Journal Published Year Pages File Type
769682 Computers & Fluids 2008 15 Pages PDF
Abstract

The operation of centrifugal pumps can generate instabilities and pressure pulsations that may be detrimental to the integrity and performance of the pump. In the present study a numerical investigation of the time variation of pressure within a complete centrifugal pump was undertaken. A range of parameters and three flow rates were investigated and the pulsations were extracted at 15 different locations covering important pump regions. The transient flow results compared reasonably with experimental data obtained in a limited experimental survey and clearly indicated the pump locations experiencing the largest pulsation levels. It was also noted that monitoring pulsations at the top dead centre of the pump volute casing would provide a better indication of internal pump pulsations than monitoring at the discharge.

Related Topics
Physical Sciences and Engineering Engineering Computational Mechanics
Authors
, ,