Article ID Journal Published Year Pages File Type
772559 Energy Conversion and Management 2010 9 Pages PDF
Abstract

In this work, we present a new automatic supervision and fault detection procedure for PV systems, based on the power losses analysis. This automatic supervision system has been developed in Matlab&Simulink environment. It includes parameter extraction techniques to calculate main PV system parameters from monitoring data in real conditions of work, taking into account the environmental irradiance and module temperature evolution, allowing simulation of the PV system behaviour in real time. The automatic supervision method analyses the output power losses, presents in the DC side of the PV generator, capture losses. Two new power losses indicators are defined: thermal capture losses (Lct) and miscellaneous capture losses (Lcm). The processing of these indicators allows the supervision system to generate a faulty signal as indicator of fault detection in the PV system operation.Two new indicators of the deviation of the DC variables respect to the simulated ones have been also defined. These indicators are the current and voltage ratios: RC and RV.Analysing both, the faulty signal and the current/voltage ratios, the type of fault can be identified. The automatic supervision system has been successfully tested experimentally.

Related Topics
Physical Sciences and Engineering Energy Energy (General)
Authors
, ,