Article ID Journal Published Year Pages File Type
774151 Engineering Failure Analysis 2013 9 Pages PDF
Abstract

Failure analysis was performed on different brass electro-valves body affected by unexpected phenomena of cracking. Through the application of optical and scanning electron microscopy, micro hardness Vickers test and X-ray diffraction, the causes of damage were identified. The study showed the dependence between roughness and residual stress associated to the tool wear. A solution to avoid the failure is finally proposed, based on the use combination of a tool with controlled wear and stress relieving heat treatment.

► Different electro-valves body were affected by phenomena of cracking. ► The failure is related to residual stresses induced by machining operations performed with wear tools. ► The use of tools with controlled wear and correct stress relieving treatment avoid the failure.

Related Topics
Physical Sciences and Engineering Engineering Industrial and Manufacturing Engineering
Authors
, , , ,