Article ID Journal Published Year Pages File Type
774443 Engineering Failure Analysis 2006 8 Pages PDF
Abstract

A failure investigation has been conducted on a stud bolt used in a ring spinning frame textile machine, which is made of austenitic stainless steel (AISI 304). The stud bolt has been found fractured after about 300 h in service. An evaluation of the failed stud bolt was undertaken to assess its integrity that included a visual examination, photo documentation, chemical analysis, micro-hardness measurement, tensile testing, and metallographic examination. The failure zones were examined with the help of a scanning electron microscope (SEM) equipped with EDX facility. Results indicate that the stud bolt fractured in rotating bending fatigue.

Related Topics
Physical Sciences and Engineering Engineering Industrial and Manufacturing Engineering
Authors
,