Article ID Journal Published Year Pages File Type
7745749 Solid State Ionics 2015 5 Pages PDF
Abstract
An approach for testing methods is described with the aim to determine the influence of different parameters on the performance of a low temperature PEMFC stack. Changes of the parameters were the stack temperature, the anode and cathode stoichiometry and the anode and cathode humidity, which have, besides the gas pressures, a major impact on the stack performance. The stack performance was evaluated using the variation at different electrical load values. Additionally, two polarization curves at different parameter settings were performed.
Related Topics
Physical Sciences and Engineering Chemistry Electrochemistry
Authors
, , ,