Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
781387 | International Journal of Machine Tools and Manufacture | 2007 | 5 Pages |
Abstract
In this study, the tool life of plasma immersion nitrogen-implanted cutting inserts while machining AISI 4140 steel has been investigated. The implantation time was 5 h and the temperature was in the range 320–520 °C. Implantation dose was ∼2×1018 ions cm−2 for all treatments. Surface topography of the implanted surfaces was obtained from atomic force microscopy. Results of the turning tests are discussed in terms of tool life (flank wear) and surface roughness of the workpieces. The results show that plasma immersion nitrogen implantation increased tool life by about 85%.
Related Topics
Physical Sciences and Engineering
Engineering
Industrial and Manufacturing Engineering
Authors
I.E. Saklakoglu, N. Saklakoglu, V. Ceyhun, K.T. Short, G. Collins,