Article ID Journal Published Year Pages File Type
7870562 Materials Science and Engineering: C 2014 7 Pages PDF
Abstract
Plasma immersion ion implantation (PIII) modifies the surface properties of polymers, enabling them to covalently immobilize proteins without using linker chemistry. We describe the use of PIII treated polycarbonate (PC) slides as a novel platform for producing microarrays of cluster of differentiation (CD) antibodies. We compare their performance to identical antibody microarrays printed on nitrocellulose-coated glass slides that are currently the industry standard. Populations of leukocytes are applied to the CD microarrays and unbound cells are removed revealing patterns of differentially immobilized cells that are detected in a simple label-free approach by scanning the slides with visible light. Intra-slide and inter-slide reproducibility, densities of bound cells, and limits of detection were determined. Compared to the nitrocellulose-coated glass slides, PIII treated PC slides have a lower background noise, better sensitivity, and comparable or better reproducibility. They require three-fold lower antibody concentrations to yield equivalent signal strength, resulting in significant reductions in production cost. The improved transparency of PIII treated PC in the near-UV and visible wavelengths combined with superior immobilization of biomolecules makes them an attractive platform for a wide range of microarray applications.
Related Topics
Physical Sciences and Engineering Materials Science Biomaterials
Authors
, , , , , , ,