Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
787114 | International Journal of Refrigeration | 2012 | 5 Pages |
Abstract
Experimental runs were done to estimate the adsorption characteristics of granular activated carbon (GAC)/R134a pair. A laboratory scale test rig was designed and built to run the experiments. The adsorption capacity of the GAC was studied at different temperatures 25 °C, 35 °C, 45 °C and 65 °C. Pressure and time were recorded during the experiments. The maximum adsorption capacity was found to be 1.68 kgR134a kgcarbon−1 at 25 °C after 1000 s. The activation energy and the exponential constant were estimated to be 9575 J mol−1 and 1.83 respectively.
Related Topics
Physical Sciences and Engineering
Engineering
Mechanical Engineering
Authors
Ahmed A. Askalany, M. Salem, I.M. Ismail, Ahmed Hamza H. Ali, M.G. Morsy,