Article ID Journal Published Year Pages File Type
788939 International Journal of Refrigeration 2007 15 Pages PDF
Abstract

The method of implicit curve-fitting and explicit-calculation has been used for fast and stable calculations of thermodynamic properties of subcritical refrigerants. In order to extend that method to the critical pressure, a method of sectional implicit curve-fitting and explicit-calculation for refrigerant thermodynamic properties is introduced in this paper. The whole data range is divided into several subsections. The requirements on the continuity of thermodynamic properties and the first order derivative of thermodynamic properties in the intersection points of subsections are indicated, and the methods to meet the requirements are presented. Quadric equations are constructed instead of curve-fitting when no data can be given. With the source data obtained from REFPROP 7.1, explicit fast calculation formulae for thermodynamic properties of R410A, covering the saturated temperature of 213.15–344.51 K and superheat of 0–65 K, are given as an example. The calculation speeds of the formulae of R410A are more than 7000 times faster than those of REFPROP 7.1 while the total mean relative deviation of the fast calculation formulae from REFPROP 7.1 is only 0.04%.

Related Topics
Physical Sciences and Engineering Engineering Mechanical Engineering
Authors
, , , ,