Article ID Journal Published Year Pages File Type
790224 International Journal of Refrigeration 2014 8 Pages PDF
Abstract

•Astronautics designed and constructed a new magnetic refrigeration system.•This system provided over 3 kW of zero-span cooling power.•The system provided 2.5 kW over a span of 11 °C.•These are the highest cooling powers yet reported for a magnetic system.

Astronautics has constructed a large-scale rotary magnetic refrigerator which was designed to provide 2 kW of cooling power over a temperature span of 12 K with Electrical Coefficient Of Performance (COPe) > 2. The system uses a NdFeB magnet assembly with peak field of 1.44 T which rotates over twelve beds arranged circumferentially. Each bed was packed with six layers of LaFeSiH of different Curie temperatures, chosen to optimize system performance over the desired span. We report here on the performance of this system at flow rates ranging from 12.5 to 21.2 L min−1. At the largest flow rate, the system produced 3042 W of cooling power at zero span and peak performance of 2502 W over a span of 11 K. To our knowledge, this represents the largest cooling power yet observed for a magnetic refrigeration system. We show that the measured performance is in good agreement with theoretical prediction.

Related Topics
Physical Sciences and Engineering Engineering Mechanical Engineering
Authors
, , , , , , , ,