Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
7915758 | Cryogenics | 2018 | 8 Pages |
Abstract
This paper reports the effects of a current sweep cycle method on reducing the screening current induced field (SCF) in a (RE)Ba2Cu3Ox (REBCO) coil. The screening current induced field in a REBCO coil causes two major problems: temporal magnetic field drift and a reduction of the central magnetic field. This is a critical problem in relation to REBCO coils, which require a homogeneous and stable magnetic field, during, for instance, nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) applications (Itoh et al., 2013; Hemmi et al., 2005; Hahn et al., 2008; Amemiya et al., 2008; Otsuka et al., 2011; Yang et al., 2013; Ahn et al., 2009; Koyama et al., 2009; Kajikawa et al., 2015). In an effort to circumvent the SCF problem, the current sweep cycle method is investigated based on experiments in this study. The experimental results show that a greater SCF reduction in a REBCO coil can be obtained by increasing the overshooting of the current sweep cycle.
Related Topics
Physical Sciences and Engineering
Materials Science
Electronic, Optical and Magnetic Materials
Authors
Young Jin Hwang, Jae Young Jang, SangGap Lee, Jiho Lee, Woo Seung Lee,