Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
7916069 | Cryogenics | 2014 | 24 Pages |
Abstract
The emissivities of thermal shield mock-up samples for ITER have been measured at sample temperatures between 80Â K and 300Â K using an optical method employing a primary standard broadband detector. These thermal shields, made from SS304L stainless steel coated with silver, are designed to operate at 80Â K, protecting the superconducting magnet system of the ITER reactor from higher temperature regions. Our results show that the silver coating of the thermal shields can have an emissivity as low as 0.0035 at 80Â K, approximately ten times lower than the emissivity of the bare polished stainless steel plate. We demonstrate that the emissivity of different regions of a thermal shield assembly can be determined in a single measurement cycle, providing further emissivity data on the insulating spacer used to separate shield plates as well as emissivity data on a silver coating repair method. The temperature dependence of the emissivity for the silver coating agrees well with a theoretical estimate based on the Drude model including phonon and surface-assisted scattering.
Keywords
Related Topics
Physical Sciences and Engineering
Materials Science
Electronic, Optical and Magnetic Materials
Authors
S.I. Woods, T.M. Jung, D.R. Sears, J. Yu,