Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
7922587 | Materials Chemistry and Physics | 2015 | 8 Pages |
Abstract
The effect of the core-shell NPs on the MRI contrast enhancement is obtained and quantified in a set of MRI of agar phantoms obtained at 7Â T magnetic field and with a imaging gradient field of 1.6Â T/m. The core-shell NPs were tested in Zebra-fish (Danio rerio) animal model. Zebra-fish MRI were obtained with animals injected with the three core-shell NPs and the contrast enhancement validated.
Keywords
Related Topics
Physical Sciences and Engineering
Materials Science
Electronic, Optical and Magnetic Materials
Authors
A. Carvalho, I. Domingues, M. Clara Gonçalves,