Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
8023856 | Surface and Coatings Technology | 2018 | 7 Pages |
Abstract
To evaluate the effects of implantation on fatigue performance of TC18 alloy, Cr and Zr were implanted into specimens using metal vapor vacuum arc plasma source (MEVVA) with a dose of 1â¯Ãâ¯l017â¯ions/cm2. The test results show that the fatigue resistance decreased after Cr implantation and Zr implantation, compared to no implanted specimen. The increase in surface roughness after implantation has been found. To analyze the effects of surface roughness produced by ion implantation, the related surface parameters and estimated effective fatigue stress concentration factors was discussed using A&R model. Apart from the residual surface stress and other factors, the surface roughness may have an influence on the fatigue limits of the implanted samples.
Related Topics
Physical Sciences and Engineering
Materials Science
Nanotechnology
Authors
Xiaohu Chen, Adriana Soveja, Michel Chaussumier, Pingze Zhang, Dongbo Wei, Feng Ding,