Article ID Journal Published Year Pages File Type
8023868 Surface and Coatings Technology 2018 51 Pages PDF
Abstract
The impedance responses of SSA top coat, TGO, and TGO-bond coat interface were reduced drastically after oxidation at 1100 °C for 10 h pre-oxidized specimen as compared to 20 and 30 h due to the compositional change of pure α-Al2O3 based TGO into more conductive NiCr2O4. The lowest diffusion coefficient, DCr3+ in the NiO lattice which reduced the formation of metal ion vacancies at the TGO-top coat interface caused to exhibit higher TGO resistance for 20 h pre-oxidized specimens over 10 and 30 h after oxidation at 1100 °C.
Related Topics
Physical Sciences and Engineering Materials Science Nanotechnology