Article ID Journal Published Year Pages File Type
8032518 Thin Solid Films 2018 8 Pages PDF
Abstract
The hardness of the mentioned zones was two to three times greater than that of the core material (AISI 316 LVM steel). Coatings deposited at temperatures up to 450 °C (Vb lower than 1000 V) have thicknesses lower than 5 μm. These coatings have good corrosion resistance but hardness on the level of 9 GPa. By increasing the process temperature above 500 °C (Vb above 1000 V), the corrosion resistance of the modification zone was depleted, an increase in hardness to a level of 14 GPa was observed. In these cases, the thickness of the modification zone was over 9 μm. The reason for the weak corrosion resistance was the formation of metal whiskers across DLC coating.
Related Topics
Physical Sciences and Engineering Materials Science Nanotechnology