Abstract
Ultrashort, low-emittance electron pulses can be created at a high repetition rate by using a TM110 deflection cavity to sweep a continuous beam across an aperture. These pulses can be used for time-resolved electron microscopy with atomic spatial and temporal resolution at relatively large average currents. In order to demonstrate this, a cavity has been inserted in a transmission electron microscope, and picosecond pulses have been created. No significant increase of either emittance or energy spread has been measured for these pulses. At a peak current of 814â¯Â±â¯2 pA, the root-mean-square transverse normalized emittance of the electron pulses is Én,x=(2.7±0.1)·10â12 m rad in the direction parallel to the streak of the cavity, and Én,y=(2.5±0.1)·10â12 m rad in the perpendicular direction for pulses with a pulse length of 1.1-1.3 ps. Under the same conditions, the emittance of the continuous beam is Én,x=Én,y=(2.5±0.1)·10â12 m rad. Furthermore, for both the pulsed and the continuous beam a full width at half maximum energy spread of 0.95â¯Â±â¯0.05 eV has been measured.
Keywords
Related Topics
Physical Sciences and Engineering
Materials Science
Nanotechnology
Authors
W. Verhoeven, J.F.M. van Rens, E.R. Kieft, P.H.A. Mutsaers, O.J. Luiten,