Abstract
An experimental research has been carried out for vertically upward two-phase flow of air-water across inverted half U-tube bundle with or without anti-vibration bars. Pressure drop characteristics in inverted half U-tube bundle and anti-vibration bars were obtained and analyzed. New correlations for total pressure drop of two-phase flow in inverted half U-tube bundle and local pressure drop of two-phase flow in anti-vibration bars were developed. The measured two-phase pressure drops in inverted half U-tube bundle of three walls in the test sections were unequal. The pressure drop in the side wall dominated the total pressure drop of two-phase flow in inverted half U-tube bundle for 57â¯â¤â¯Gâ¯<â¯114â¯kg·mâ2·sâ1, while the pressure drop in the front wall dominated for 114â¯<â¯Gâ¯â¤â¯143â¯kg·mâ2·sâ1. An obvious mass velocity effect was observed for the total pressure drop of two-phase flow in inverted half U-tube bundle. For a given Martinelli parameter, the total pressure drop of two-phase flow in inverted half U-tube bundle decreased with an increasing mass velocity. The two-phase local pressure drop data of anti-vibration bars could be fitted well in terms of the Martinelli parameter and mass velocity.
Keywords
Related Topics
Physical Sciences and Engineering
Energy
Energy Engineering and Power Technology
Authors
Y.P. Zhang, K. Zhang, J. Wang, G.H. Su, W.X. Tian, S.Z. Qiu,