Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
8067060 | Annals of Nuclear Energy | 2018 | 10 Pages |
Abstract
Our calculation results also display that fuel temperature coefficient (FTC) is still negative after adding minor actinide to reactor. In comparison with the standard AP1000 reactor core, the extent of the negative feedback effect of FTC after loading minor actinides is reduced to some extent; the moderator temperature coefficient (MTC) improves the negative feedback effect of the reactor core to a great extent. Taking into account all analytical results about FTC and MTC, the total negative feedback effect on reactor power level changes is improved after loading minor actinides to AP1000 reactor for transmutation. The transmutation rate calculation results show that AP1000 reactor can incinerate 44.0â¯kg MA nuclides after one year fuel cycle. So AP1000 reactor can incinerate almost 2 times the annual MA yield from a typical PWR reactor.
Keywords
Related Topics
Physical Sciences and Engineering
Energy
Energy Engineering and Power Technology
Authors
Bin Liu, Rendong Jia, Ran Han, Xuefeng Lyu, Jinsheng Han, Wenqiang Li,