Article ID Journal Published Year Pages File Type
8067077 Annals of Nuclear Energy 2018 12 Pages PDF
Abstract
As a result, three different mechanisms at the onset of flooding in counter-current were clarified, and are strongly affected by liquid superficial velocity. At low liquid superficial velocity (JL), the flooding mechanism is triggered by the presence of wavy interface along the horizontal pipes in the form of a liquid blockage on the elbow. At the medium JL, the slug was detected along the horizontal pipe. However, the slug collapses immediately since the water is insufficient to maintain the blockage. At high JL, the slug occurs and travels along the horizontal pipe until the elbow. Moreover, the effect of the length of horizontal pipe on the interfacial behavior of air water counter current flow also can be explained. As the length of the horizontal pipe decreases, the onset of flooding occurs at a higher gas liquid mass flow rate.
Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology