Article ID Journal Published Year Pages File Type
8067174 Annals of Nuclear Energy 2018 9 Pages PDF
Abstract
The rod insertion method for control rod worth measurement is explained and past as well as recent developments are outlined. The original methodology is updated with a more consistent use of the flux redistribution correction, conversion from dynamic to static reactivity and a new procedure to account for the so-called reactivity overshoot. As an example, the procedure is applied to real measured data from Krško NPP. Resulting integral and differential worth curves are compared with reference measurements by the boron dilution method, where a previously unattainable match is observed. Additional research is presented in order to assess the remaining small deviations. Besides other advantages, the rod insertion method is demonstrated to produce results that are in excellent agreement with those of boron dilution method and can therefore be used as replacement.
Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , ,