Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
8068614 | Annals of Nuclear Energy | 2015 | 9 Pages |
Abstract
Against all expectations it turned out that the usage of sampled response values has no practical effect on the performance of reaction rate estimators when using TMS with elevated basis cross section temperatures (EBT), i.e. the usual way. With 0 Kelvin cross sections a significant increase in the variances of capture rate estimators was observed right below the energy region of unresolved resonances, but at these energies the figures-of-merit could be increased using a simple resampling technique to decrease the variances of the responses. It was, however, noticed that the usage of the TMS method increases the statistical deviances of all estimators, including the flux estimator, by tens of percents in the vicinity of very strong resonances. This effect is actually not related to the usage of sampled responses, but is instead an inherent property of the TMS tracking method and concerns both EBT and 0Â K calculations.
Keywords
Related Topics
Physical Sciences and Engineering
Energy
Energy Engineering and Power Technology
Authors
Tuomas Viitanen, Jaakko Leppänen,