Article ID Journal Published Year Pages File Type
8069262 Annals of Nuclear Energy 2014 5 Pages PDF
Abstract
In this work, we evaluated the neutron-gamma discrimination capability of EJ301 and EJ339A liquid scintillation detectors via the pulse shape discrimination (PSD) method. Both simulation and experimental results are reported. The Geant4 simulation toolkit was used to model the scintillation process inside the scintillator, for neutron and gamma events, respectively. For the experiments, a high-speed digitizer was used to acquire data, which was then processed in MATLAB. This work compared the PSD performance of two liquid scintillation detectors and demonstrated the capability of Geant4 with regard to simulation of pulse shape.
Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, ,