Abstract
⺠87-89% of 134Cs and 137Cs in radioactive ash were removed by three washings. ⺠Electro-decontamination for 8-10 days lowered the radioactivity of ash below 2 Bq/g. ⺠Electrokinetic decontamination efficiency for 6.5 h-4.3 day was the highest. ⺠Electrokinetic decontamination efficiency after 7.2 days promptly became low.
Keywords
Related Topics
Physical Sciences and Engineering
Energy
Energy Engineering and Power Technology
Authors
Gye-Nam Kim, Seung-soo Kim, Hye-Min Park, Wan-Suk Kim, Uk-Ryang Park, Jei-Kwon Moon,