Article ID Journal Published Year Pages File Type
8070766 Energy 2018 41 Pages PDF
Abstract
Present paper highlights the effect of under-loading the engine and the hydraulic system of a Front End Loader (FEL). In this respect, a novel idea to modify load cycle of engine is applied in the Conventional Hydrostatic-Split Power Transmission (CH-SPT) drive by incorporating additional load on the drive through the DC generator. The load on modified system, called Regenerative Hydrostatic-split power transmission (RH-SPT) drive is the loading pump unit and DC generator unit, which is used for generating equivalent duty cycle of the FEL and electrical energy generation, respectively. The excess load of the DC generator is varied through the controller depending on engine's optimal efficient torque and the load torque. This assists the engine to operate in its efficient zone during under-loading conditions. Also, a MATLAB®/Simulink model is made and validated experimentally. The validated model is analysed to compare the performances and fuel consumption of conventional HST drive, CH-SPT drive and RH-SPT drive. It is concluded that with increase in fuel consumption of the RH-SPT system by 10% and 56% of the CH-SPT and conventional drive system, the electric power regeneration through the DC generator increases by 21% and 200% of the maximum power generated in the respective system.
Related Topics
Physical Sciences and Engineering Energy Energy (General)
Authors
, , ,