Article ID Journal Published Year Pages File Type
8076576 Energy 2014 10 Pages PDF
Abstract
The increase in throughput or reduction in the operational costs is the common example of change in production criteria in retrofit projects. In this study, the condensate stabilization unit of a gas refinery, which is one of the most energy consuming units in natural gas refineries, is considered for analysis and retrofitting study. This unit comprises of a two-stage compressor and a side-reboiler associated with the stabilization column that uses HP steam as hot utility. It is shown that by applying the optimum pressure drops method for debottlenecking of this unit, after 20% increase in throughput, utility consumption can be maintained at existing level, if 1554 m2 of additional heat transfer area is installed.
Related Topics
Physical Sciences and Engineering Energy Energy (General)
Authors
, , ,