| Article ID | Journal | Published Year | Pages | File Type | 
|---|---|---|---|---|
| 8082629 | Journal of Environmental Radioactivity | 2015 | 6 Pages | 
Abstract
												The car-borne survey system KURAMA-II, developed by the Kyoto University Research Reactor Institute, has been used for air dose rate mapping after the Fukushima Dai-ichi Nuclear Power Plant accident. KURAMA-II consists of a CsI(Tl) scintillation detector, a GPS device, and a control device for data processing. The dose rates monitored by KURAMA-II are based on the G(E) function (spectrum-dose conversion operator), which can precisely calculate dose rates from measured pulse-height distribution even if the energy spectrum changes significantly. The characteristics of KURAMA-II have been investigated with particular consideration to the reliability of the calculated G(E) function, dose rate dependence, statistical fluctuation, angular dependence, and energy dependence. The results indicate that 100 units of KURAMA-II systems have acceptable quality for mass monitoring of dose rates in the environment.
											Related Topics
												
													Physical Sciences and Engineering
													Energy
													Nuclear Energy and Engineering
												
											Authors
												S. Tsuda, T. Yoshida, M. Tsutsumi, K. Saito, 
											